H00251-31043

HPLC Column: Ultisil XB-C18, 5μm, 4.5×250mm(for belladonna extract)

Ultisil XB-C18 is one of the most versatile C18 analytical columns on the market. It features advanced bonding and double-endcapping technology, delivering nearly perfect peak shapes. This column is ideal for analyzing complex matrix samples and provides excellent peak shapes for acidic and basic compounds. It is particularly effective for the separation of traditional Chinese medicine compounds.

Request a quoteDownload the datasheet

HPLC Column: Ultisil XB-C18, 5μm, 4.5×250mm(for belladonna extract)

Description

This is the specialized version for belladonna extract. See here for the Standard version .

Ultisil Series HPLC Columns are based on ultra-pure (purity > 99.999%) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility. Ultisil column is the best choice for method development. owing to complete bonding chemistries and stable performance

Features

  • Ultra-pure spherical porous silica, purity > 99.999%
  • Wide pH range: 2.0-8.0
  • High efficiency: theoretical plate > 80000/m
  • Excellent peak symmetry: tailing factor=0.95~1.05
  • Exceptional lot-to-lot reproducibility

Trace Amount Metal Contents Test

A useful chromatographic test of trace amount of metal contents in the column is to compare the peak symmetry of one pair of positional isomers, 4,4’-dipyridyl and 2,2’-dipyridyl, and a neutral chelating reagent, 1,2-dihydroxylnaphthalene. 4,4’-dipyridyl, which cannot form chelating complex with metal, is used as a reference. 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene, which are chelating reagents, are sensitive to trace amount metal in silica. When a C18 column based on type A silica or other so-called type B silica with higher metal content is used, the peaks of 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene would tail or even totally disappear.

ColumnUltisil® XB-C18, 4.6 ×150 mm, 5 μm
Mobile Phase20 mM phosphate(pH 7.6) / methanol=55/45
Flow Rate1.0 mL/min
Detector215 nm
Temperature25°C
Injection Volume1 μL
Samples1) 4,4’-Dipyridyl; 2) 2,2’-Dipyridyl; 3) 1,2-Dihydroxylnaphthalene

Conclusion: Ultisi XB-C18 provides good peak shapes in the separation of these three compounds under pH 7.6, which indicates Ultisil silica contains hardly any metals.

Specifications

Particle size5 µm
Pore size120 Å
ID4.5 mm
Length250 mm
PhaseXB-C18
USP ClassificationL1
Separation ModeReversed Mode
pH Range2.0-8.0
Surface Area320m2/g
Carbon Load17%
Max. Pressure40 MPa
EndcappedYes
Max. Temp.60°C(pH≤6.5) and 40°C(pH>6.5)
Particle ShapeSpherical
Similar Columns (Agilent)Agilent ZORBAX Eclipse XDB-C18; Agilent ZORBAX TYPE A Silica C18; Agilent Pursuit XRs C18; Agilent Pursuit XRs Ultra C18; Agilent HC (2)/TC (2) HC-C18 (2)
Similar Columns (Phenomenex)Phenomenex Columbus C18; Phenomenex Luna C18; Phenomenex Luna Omega C18; Phenomenex Prodigy ODS-2
Similar Columns (Sepax)Sepax Sepax GP-C18; Sepax Sepax Bio-C18-200; Sepax Sepax Sapphire C18
Similar Columns (Supelco)Supelco Discovery C18; Supelco Discovery HS C18
Similar Columns (Thermo)Thermo BETASIL C18; Thermo Fluophase RP 100A perfluorohexyl; Thermo Hypersil GOLD C18; Thermo Hypersil ODS (C18); Thermo Hypersil ODS-2 (C18); Thermo Acclaim 120 C18; Thermo Acclaim AMG C18; Thermo HyPURITY C18; Thermo HyPURITY Aquastar; Thermo Syncronis C18
Similar Columns (Waters)Waters XBridge BEH 130-C18 (PST); Waters XSelect HSS-C18; Waters Symmetry C18; Waters Sunfire C18; Waters Spherisorb ODS2 fully end capped; Waters Delta-Pak C18 (100A); Waters BioSuite C18 PA-A