Una unidad de AKRIBIS One

Blossmate_Polar-Propylamide-Series

Blossmate Polar-Propylamide

Blossmate Polar-Propylamide column provides separation forces akin to a HILIC-NH 2 phase but with distinct selectivity. It exhibits low bleed in ELSD and MS detection and offers a longer operational lifespan than standard NH 2 columns.

Solicitar cotizaciónDescargar ficha técnica

Blossmate Polar-Propylamide

Description

Blossmate series column is a high-end HPLC column launched by Welch Materials. Compared with Xtimate and Ultisil series, Blossmate’s column performance and reproducibility have been improved in an all way and it is especially suitable for the detection of multi-component impurity projects.

Features

  • It adopts a new generation of ultra-high-purity fully porous silica gel, which greatly ensures the perfect column eciency and separation performance.
  • Each column is tested individually with special testing prodecure under stricter standards, which guarantee the quality and performance of the column.
  • Extremely stable separation performance to ensure better analysis reproducibility and perfect peak shape.
  • Excellent batch-to-batch reproducibility, especially for the analysis of multi-impurity component applications.
  • Blossmate uses a unique bonding process that enables the column to withstand high water phase, high pH experimental environments.

Blossmate Series Silica

Blossmate series HPLC column uses a new fully porous silica packing materials, which has higher silica purity, more uniform particle size and more uniform pore size distribution. Under the unique packing process and strict quality control conditions, Blossmate silica not only has the high mechanical strength and high column effciency, but also has the perfect and excellent reproducibility, makes it to be the best choice for highly reproducible project.

Blossmate series columns provide better reproducibility, higher efficiency and higher peak capacity.

Blossmate series columns use a new high-purity fully porous silica and Welch's unique bonding process and double end-capping techniques to ensure that the silica surface has a higher inertness, and thus has a more symmetrical peak shape and higher column efficiency. Blossmate columns adopt high-standard strict quality control conditions to ensure that each column has undergone strict quality screening before leaving the factory, which makes the column have better reproducibility and higher peak capacity.

Blossmate Polar-Propylamide

Bonding Phase Introduction

Blossmate C18: Blossmate C18 is a general-purpose, highly versatile column which suitable for sample analysis of many complex components, as well as flexible method development under a range of chromatographic conditions.

Blossmate Aqs-C18: Blossmate Aqs C18 is a C18 reversed-phase column compatible with pure water phase and pure salt phase. Under the condition of high proportion of water phase, the column still has excellent stability and high column efficiency, suitable for analysis of hydrophilic and highly polar samples.

Blossmate ST-C18: Blossmate ST-C18 column adopts a special silica matrix surface treatment technology, while maintaining the high mechanical strength and high column efficiency of the silica matrix, the pH tolerance range of the column is extended to 1.0-11.0, suitable for the analysis of basic samples, and in method development at higher pH conditions.

Blossmate C4: Welch Materials has launched a new Blossmate C4 column, which fully meets the needs of detecting various biological samples, and provides customers with a HPLC column with higher accuracy, faster peak output, lower cost and a wider range of protein measurement

Blossmate Phenyl: Welch Materials has launched a new Blossmate Phenyl column to fully meet the needs of detecting various biological samples, providing customers with higher accuracy, faster peak output, lower cost and a wider range of protein measurement columns.

Specifications

Particle size5 µm
Pore size120 Å
ID4.6 mm
Length150 mm, 250 mm
PhaseBlo-Polar-Propylamide
Separation ModeHILIC Mode
pH Range2.0-8.0
Surface Area300m2/g
Carbon Load7%
Max. Pressure40 MPa
Max. Temp.60°C(pH≤6.5) and 40°C(pH>6.5)
Particle ShapeSpherical