Una unidad de AKRIBIS One

Differential-Pressure-Decay-Series

High Precision Differential Pressure Decay Leak Detector

The differential pressure decay leak detector uses the differential pressure sensor as the sensing element, and fills/evacuates the inside of the part to be tested to a specified pressure, so as to judge whether the part to be tested leaks or not and the leakage size accordina to the attention value of the internal pressure.

Solicitar cotización

High Precision Differential Pressure Decay Leak Detector

Advantages

  • Accurate detection, interactive user experience
  • Intelligent Interconnection System
  • Massive data storage, retrieval, and processing capability
High Precision Differential Pressure Decay Leak Detector

Product Performance

1. Modular Integrated design
2. Automatic evacuation pressure and time setting, high leak detection efficiency;
3.It is suitable for direct pressure and flow rate leakage detection methods, and compatible with the use of single and multi-station requirements, to achieve one device to detect multiple products
4. Wireless remote-control function (optional);

Applications

It is widely used in production line industries such as refrigeration and air conditioning, automotive parts, carbonated beverage containers food packages and aerosol packaging, as well as in the manufacture of steam products, gas bottles, fire extinguishers, tire valves, and numerous other products including all vacuum systems.

High Precision Differential Pressure Decay Leak Detector

Main Models Parameters

Parameter---
Differential Pressure SensorDisplay PrecisionThe value can be set to 0 to 4 decimal places
Sensor Range±2000Pa
Sensor Error±0.1%F.S
Sensor Pressure13.8MPa
StandardCH050Mechanical Pressure Regulating1~20kPa, 1~50kPa, 5~100kPa
CH050DElectronic Pressure Regulation1~20kPa, 1~50kPa, 5~100kPa
CH600Mechanical Pressure Regulating10kPa~ 600kPa
CH600DElectronic Pressure Regulation10kPa~ 600kPa
ZF600Customized-100~-1kPa, 50~2400kPa, 200~4000kPa
ZF2400Customized-100~-1kPa, 50~2400kPa, 200~4000kPa
Standard-Double StationZF2-600Mechanical Pressure Regulating10~600kPa
ZF2-600DElectronic Pressure Regulation10~600kPa
ModularCH600PMechanical Pressure Regulating10~600kPa
Direct Pressure SensorSensor Error+0.1%F.S.
Display PrecisionThe value can be set to 0 to 4 decimal places
Display UnitTest PressurekPa,MPa,kg/cm2,psi,mbar. bar,Torr. mmH,0,mmHg
Leakage RatePa,kPa,Pa/s,Pa.m3/s,mL/s,mL/min,mL/h. L ./min. L /h. SCCM
Parameter Program Number64 groups (1~64)
Test Beat Setting0 ~ 3600seconds
Power SupplyAC 220V+10%,50Hz
Test Pressure SourceClean, dry, adequate flow, not less than 600KPa and 100KPa above the test pressure source
Environment TemperatureWorking temperature: -5°C~40°C,Stock temperature: -20°C~70°C
HumidityBelow 80%RH, frostless
Overall DimensionsStandard321mmx440mmx206mm
WeightStandard20kgs

Modular 191mmx249mmx268mm Modular 10kgs

Configurar el equipo

Elija modelo, sondas y accesorios. Las combinaciones incompatibles se bloquean solas; el resto de las reglas se verifica al agregar el equipo a la cotización.

Escribir por WhatsApp