Direct-pressure airtightness leak detector uses direct-pressure sensor as sensing element, and fils/evacuates compressed air or nitrogen with specified pressure into the part to be tested, and judges whether there is leakage and the leakage size of the part to be tested according to the attenuation value of its internal pressure.

Solicitar cotización

Large Range Direct Pressure Decay Leak Detector

Advantages

  • Accurate detection and interactive experience
  • Intelligent interconnection system
  • Mass data storage, retrieval, and processing capabilities
Large Range Direct Pressure Decay Leak Detector

Description

Introduction of Air Tightness Leak Detector

Product Performance

1. High precision components, efficient and stable, high detection accuracy

2. Integrated structure, small size and light weight

3. High resolution full colour touch screen, friendly human-machine interface, easy to learn and use

4. EMC testing, strong anti-interference capability, to ensure the safety and reliability of the whole machine

5. Multi-interface control: multiple interfaces for PC, PLC, USB stick, scanner, printer, etc.

6. Large storage capacity: 10,000 groups of records, searchable by date, job number and workpiece number
Applications
Automobile, new energy, electronics, medical, food.

Large Range Direct Pressure Decay Leak Detector

Air Tightness Direct Pressure Leak Detector

Parameter---
StandardZH2400Customized50KPa~2400KPa(optional)
Standard-(four-channel)ZH600-XCustomized10KPa~500KPa(optional)
Direct pressure sensorSensor error±0.1%F.S.
Display precisionThe value can be set to 0 to 4 decimal places
Display unitTest pressurePa, kPa, kg/cm 2 , psi, mbar, bar, Torr, mmH 2O, mmHg,MPa
LeakagePa,kPa,Pa/s,kPa/s,kPa/min,mL/s,mL/min,mL/h,L/min,L/h,SCCM
Parameter program number64 groups (1~64), Switchable via I/O or communication.
Test beat setting0 ~ 3600 seconds
Power supplyAC 220V±10%,50Hz
Test pressure sourceClean, dry, adequate flow, not less than 500KPa and 100KPa above the test pressure source
DimensionStandard321mm×440mm×206mm
Standard(four-channel)431*460*208mm
WeightStandard15kg
Standard(four-channel)20kg

Configurar el equipo

Elija modelo, sondas y accesorios. Las combinaciones incompatibles se bloquean solas; el resto de las reglas se verifica al agregar el equipo a la cotización.