Una unidad de AKRIBIS One

DLC_Diamond-Coated_HPLC_Columns-Series

DLC Diamond-Coated HPLC Columns

The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation. DLC HPLC Columns are ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.

Solicitar cotizaciónDescargar ficha técnica

DLC Diamond-Coated HPLC Columns

Description

Xtimate DLC C18 column utilizes Welch's patented organic-inorganic hybrid surface technology to modify the silica gel matrix. Specifically designed for liquid chromatography method development, it allows the use of a variety of mobile phase systems across a wide pH range and temperature conditions. Even under the most stringent conditions, it offers highly stable performance and a longer lifespan, with a longer service life than regular C18 columns under standard conditions.

Xtimate DLC Phenyl-Hexyl: Xtimate DLC Phenyl-Hexyl column utilizes Welch's patented organic-inorganic hybrid surface technology to modify the silica gel matrix, extending the pH stability range to 1.0–12.5. It offers excellent selectivity for compounds containing phenyl and short-chain alkyl groups, with strong retention for aromatic, polar, and amine-containing compounds.

DLC Diamond-Coated HPLC Columns

Xtimate DLC Bio SEC-300: Xtimate DLC Bio SEC column features ultrapure silica microspheres as matrices, with a uniform surface bonded with a hydrophilic polymer of nanometer thickness. It effectively reduces the adsorption of biological samples on the column, making it ideal for the analysis of proteins, antibodies, cytokines, and other biological samples.

Xtimate DLC SEC-300: Xtimate DLC SEC column is based on porous silica particles matrix, with its surface protected by derivatization with diol functional ligands to prevent interactions with proteins. The dual-bonding mechanism minimizes nonspecific adsorption of water-soluble polymers, proteins, biomolecules, enzymes, and peptides. It is widely used for the separation and analysis of water-soluble polymers and biological macromolecules.

Xtimate DLC SEC-300: Xtimate SEC column is based on porous silica particles matrix, with its surface protected by derivatization with diol functional ligands to prevent interactions with proteins. The dual-bonding mechanism minimizes nonspecific adsorption of water-soluble polymers, proteins, biomolecules, enzymes, and peptides. It is widely used for the separation and analysis of water-soluble polymers and biological macromolecules.

DLC Diamond-Coated HPLC Columns

Ultisil DLC SiO2: Ultisil DLC SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the separation of highly polar and lipophilic compounds.

Ultisil DLC XB-C18: Ultisil DLC XB-C18 is one of the most versatile C18 analytical columns on the market. It features advanced bonding and double-endcapping technology, delivering nearly perfect peak shapes. This column is ideal for analyzing complex matrix samples and provides excellent peak shapes for acidic and basic compounds. It is particularly effective for the separation of traditional Chinese medicine compounds.

Ultisil DLC XB-C8: Ultisil DLC XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and neutral compounds. With slightly weaker retention than C18, it is recommended for the separation of strongly hydrophobic compounds.

DLC Diamond-Coated HPLC Columns

Ultisil DLC XB-Phenyl: Ultisil DLC XB-Phenyl column features a unique stationary phase bonding and double endcapping technology, ensuring superior peak symmetry. It offers distinct selectivity compared to straight-chain alkane, providing excellent separation for aromatic and polar compounds. It serves as an ideal replacement for most phenylpropyl-bonded silica columns on the market, with low UV and MS bleed.

Ultisil DLC XB-NH2: Ultisil DLC XB-NH 2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or carbonyl groups, as well as reducing sugars.

Ultisil DLC XB-NH2: Under normal-phase elution conditions, it is suitable for analyzing polar compounds, tocopherols, and certain organic compounds soluble in alkanes, alkenes, and aromatic hydrocarbons.

Ultisil DLC XB-CN: Ultisil DLC XB-CN column is suitable for highly hydrophobic samples and compounds that cannot be eluted on conventional reversed-phase columns. In normal-phase chromatography, the cyano-bonded phase can serve as an alternative to silica, offering faster equilibration and more consistent surface activity compared to non-derivatized silica.

Ultisil DLC Diol: Ultisil DLC Diol is a normal-phase column offering superior stability and reproducibility compared to silica and amino columns, as well as enhanced selectivity and peak shape. Its unique bonding technology ensures stable stationary phase structure, while strict manufacturing processes guarantee excellent batch-to-batch reproducibility.

Ultisil DLC AQ-C18: Ultisil DLC AQ-C18 is a HPLC column designed to withstand 100%–0% aqueous environments. It features a polar group as the endcapping reagent, with moderate carbon loading and low alkyl chain bonding density, offering moderate retention. Compared to XB-C18, it has a weaker ability to adsorb impurities. This column is ideal for the analysis of polar samples, such as water-soluble vitamins, amino acids, and other hydrophilic compounds.

Ultisil DLC LP-C18: Ultisil DLC LP-C18 column is a HPLC column designed to withstand 100% aqueous to 100% organic solvents. It features steric hindrance side-chain protection to shield hydroxyl groups and adopts a non-endcapped process. With strong spatial selectivity, it exhibits high orthogonality to conventional C18 columns, making it a suitable alternative for analytes that are difficult to separate on standard C18 columns. It demonstrates low stationary phase bleed under strongly acidic conditions, as an ideal baseline noise can be observed even when using an ELSD detector.

Ultisil DLC Polar RP: Ultisil DLC Polar RP is a reversed-phase column with selectivity distinct from conventional C18. It incorporates embedded polar groups, allowing the alkyl phase to remain solvated even in highly aqueous mobile phases (up to 100% water) without hydrophobic collapse. It offers enhanced retention and selectivity for polar compounds.

Ultisil DLC XB-C4: Ultisil DLC XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.

Ultisil DLC PFP: Ultisil PFP column is a phenyl column where fluorine atoms replace hydrogen atoms on the reversed-phase stationary phase carbon chain. It offers high selectivity for fluorinated and halogenated compounds. With strong geometric and steric shape selectivity, it effectively separates structurally similar compounds that are difficult to resolve with alkyl stationary phases.

Ultisil DLC Alk C18: The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation. The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation. DLC HPLC Columns are ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.

Ultisil DLC Alk C18: Ultisil DLC Alk C18 column features a mixed stationary phase with hydrophobic and electrostatic interactions, along with HILIC properties. It allows for rapid separation of similar samples by adjusting the mobile phase.

Ultisil DLC Plus C18: Ultisil DLC Plus C18 column has a lower specific surface area, slightly larger pore size, and lower carbon loading, resulting in weaker retention compared to XB-C18. The double end-capping process ensures excellent peak shape when analyzing acidic and basic polar compounds.

Ultisil DLC XS-C18: Ultisil DLC XS-C18 utilizes a unique multilayer bonding process with high bonding density and close ligand spacing, providing excellent spatial shape selectivity. It offers high column efficiency, high column capacity, and high carbon loading, resulting in strong compound retention and exhibiting outstanding steric hindrance selectivity. The column is particularly effective for separating small-molecule isomers, including structural and positional isomers.

Ultisil DLC UHPLC XB-C18: Ultisil DLC UHPLC XB-C18 is based on 1.8 µm high-purity silica and can withstand pressures up to 15,000 psi. Being a versatile C18 analytical column, it is ideal for analyzing complex matrix samples and provides excellent peak shapes for acidic and basic compounds.

Ultisil DLC UHPLC HILIC Amphion II: Ultisil UHPLC HILIC Amphion II column features a zwitterionic (amphion) structure containing both positively and negatively charged centers. This unique composition significantly enhances the retention of acidic and basic compounds through ion-exchange mechanisms. With excellent hydrophilicity, this stationary phase enables effective HILIC-mode separation of polar, hydrophilic small molecules and basic compounds. Compared to traditional silica- and amino-based HILIC materials, it offers superior reproducibility and more stable HILIC separation performance.

The Ultimate Experience of DLC Columns

  • Enhancing the inner surface of the chromatography column with strong hydrophobicity overcomes the adverse effects of the column wall on separation.
  • The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation.
  • Ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.

Detection of Bovine Serum Albumin

Sample Solution:A precise amount of Bovine Serum Albumin (BSA) was accurately weighed, dissolved in the mobile phase, and diluted to achieve a sample solution in which every 1mL contained 0.1mg of the sample

Conclusion: The Diamond like carbon column exhibited significantly increased response values.

DLC Diamond-Coated HPLC Columns

Conclusion:

1.The diamond column minimizes the specific adsorption behavior of the chromatographic column tube, achieving efficient separation while showing higher sensitivity and response values.

2. The peak signal of the diamond column can be increased several times, indicating that it has obvious advantages in testing metal-sensitive compounds.

Specifications

LinesUltisil DLC AQ-C18, Ultisil DLC Alk C18, Ultisil DLC Diol, Ultisil DLC LP-C18, Ultisil DLC PFP, Ultisil DLC Plus C18, Ultisil DLC Polar RP, Ultisil DLC SiO2, Ultisil DLC UHPLC HILIC Amphion II, Ultisil DLC UHPLC XB-C18, Ultisil DLC XB-C18, Ultisil DLC XB-C4, Ultisil DLC XB-C8, Ultisil DLC XB-CN, Ultisil DLC XB-NH2, Ultisil DLC XB-Phenyl, Ultisil DLC XS-C18, Xtimate DLC Bio SEC-300, Xtimate DLC C18, Xtimate DLC Phenyl-Hexyl, Xtimate DLC SEC-300
Particle size1.8 µm, 3 µm, 5 µm
Pore size120 Å, 300 Å
ID2.1 mm, 4 mm, 4.6 mm, 7.8 mm, 21.2 mm
Length50 mm, 100 mm, 125 mm, 150 mm, 250 mm, 300 mm
Surface Area160m2/g, 320m2/g
EndcappedNo, Yes
Particle ShapeSpherical

Configurar el equipo

Elija modelo, sondas y accesorios. Las combinaciones incompatibles se bloquean solas; el resto de las reglas se verifica al agregar el equipo a la cotización.

Documentos

Escribir por WhatsApp