Uma unidade da AKRIBIS One

CEMS1200

CEMS 1200 Flue Gas Emission Monitoring System

The CEMS 1200 system equipment consists of a gaseous pollutant monitoring sub-system, a particulate matter monitoring sub-system, a flue gas parameter monitoring sub-system and a data acquisition and processing sub-system, which can continuously monitor a number of relevant parameters such as SO, NOx, O2, CO, CO2, HCI, soot (particulate matter) concentration, flue gas flow rate, flue gas pressure, flue gas humidity and statistical emission rates and total emissions.

Solicitar cotação

CEMS 1200 Flue Gas Emission Monitoring System

Advantages

  • Direct measurement of NO2.
  • Easy maintenance.
  • Configurable with flexibility.
CEMS 1200 Flue Gas Emission Monitoring System

Product Performance

1. Pulsed xenon lamp light source with a service life of 10 years.
2. High reliability due to the use of grating spectroscopy and array sensors with no moving parts.
3. Dust detector with integrated design, compact and reliable.

4. The use of the hot-wet method (temperature can be set between 120°C and 200°C) for SO2 and NOx measurement, avoiding inaccurate measurement due to SO2 absorption by condensate and corrosion of the instrument by the sulphite formed.

5. SO2, NOx gas analysis using differential absorption spectroscopy (DOAS), effectively solve the impact of water, dust and other factors on the measurement accuracy.

Applications

Steel plants, cement plants, chemical plants, etc.

CEMS 1200 Flue Gas Emission Monitoring System

Specifications

Product NameCEMS Online Continuous Emission Monitoring System for Nitrogen Oxide of Flue Gas
Product Size930*730*2010mm
Weight177KGS
Measure MethodUV Differential Method
Nitrogen Oxide MeasurementHeat Resistance Moisture Meter
Contaminant RangeSO 2 concentration 0-45/100 mg/ m 3 NO X concentration 0-45/100 mg/ m 3 O 2 content 0-25%
Pre-processingCondensing Method
Humidity meter measurementsHeat Resistance Moisture Meter
Oxygen contentElectrochemical