Ultisil_XB-SCX-Series
Ultisil XB-SCX
Ultisil XB-SCX column is a classic cation exchange column from Welch Materials, featuring a silica-based matrix with aromatic sulfonic acid as the bonded phase.
Solicitar cotaçãoBaixar ficha técnica
Ultisil_XB-SCX-Series
Ultisil XB-SCX column is a classic cation exchange column from Welch Materials, featuring a silica-based matrix with aromatic sulfonic acid as the bonded phase.
Solicitar cotaçãoBaixar ficha técnica
Ultisil Series HPLC Columns are based on ultra-pure (purity > 99.999%) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility. Ultisil column is the best choice for method development. owing to complete bonding chemistries and stable performance
A useful chromatographic test of trace amount of metal contents in the column is to compare the peak symmetry of one pair of positional isomers, 4,4’-dipyridyl and 2,2’-dipyridyl, and a neutral chelating reagent, 1,2-dihydroxylnaphthalene. 4,4’-dipyridyl, which cannot form chelating complex with metal, is used as a reference. 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene, which are chelating reagents, are sensitive to trace amount metal in silica. When a C18 column based on type A silica or other so-called type B silica with higher metal content is used, the peaks of 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene would tail or even totally disappear.
| Column | Ultisil® XB-C18, 4.6 ×150 mm, 5 μm |
|---|---|
| Mobile Phase | 20 mM phosphate(pH 7.6) / methanol=55/45 |
| Flow Rate | 1.0 mL/min |
| Detector | 215 nm |
| Temperature | 25°C |
| Injection Volume | 1 μL |
| Samples | 1) 4,4’-Dipyridyl; 2) 2,2’-Dipyridyl; 3) 1,2-Dihydroxylnaphthalene |
Conclusion: Ultisi XB-C18 provides good peak shapes in the separation of these three compounds under pH 7.6, which indicates Ultisil silica contains hardly any metals.
| Particle size | 3 µm, 3.5 µm, 5 µm, 10 µm |
|---|---|
| Pore size | 120 Å, 300 Å |
| ID | 2.1 mm, 3 mm, 4 mm, 4.6 mm, 6 mm |
| Length | 50 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm |
| Phase | XB-SCX |
| USP Classification | L9 |
| Separation Mode | Ion Exchange |
| pH Range | 2.0-8.0 |
| Surface Area | 90m2/g, 320m2/g |
| Carbon Load | 5%, 12% |
| Max. Pressure | 40 MPa, 60 MPa |
| Endcapped | No |
| Max. Temp. | 60°C(pH≤6.5) and 40°C(pH>6.5) |
| Particle Shape | Spherical |
Escolha modelo, sondas e acessórios. As combinações incompatíveis são bloqueadas na hora; as demais regras são verificadas ao adicionar o equipamento à cotação.
Carregando as opções…
É possível colar um código e a configuração se monta sozinha.
São cotados à parte: não é preciso configurar o equipamento.
Instrumentos para cotar
Ainda não há instrumentos. É possível escrever mesmo assim: um especialista responde.