GC6100

GC6100 Gas Chromatograph

GC6100 Gas Chromatograph

Solicitar cotação

GC6100 Gas Chromatograph

Description

GC6100 Gas Chromatography with FID Detector
Technical Parameters of GC6100 Gas Chromatography

1. High precision

1.1 Very low noise, FID noise is better than the international leading level;
1.2 High sensitivity detector, low baseline drift;
1.3 Good reproducibility of peak area and retention time;
1.4 High temperature control accuracy and good stability, the column thermostat provides a constant temperature environment for the effective separation and detection of various components.

2. Flexibility and scalability

2.1 Optional multiple detectors (FID, FPD, ECD);
2.2 Any two detectors and two chromatographic columns can be installed at the same time; It can have three independent circuits, gas system and three signal output terminals at the same time;
2.3 Flexible syringe injection system, optional autosampler or six-port valve injection.

Product Application

Environmental Protection: Trace Toxicants in Air and Water Contaminated Areas Analysis, monitoring and research

Biochemistry: clinical applications, pathology and toxicology studies.

GC6100 Gas Chromatograph

Specifications

Power Supply220V ±10%, 50Hz ±2%
Ambient Temperature5°C to 40°C
Relative Humidity20% to 85%

Technical Specifications

Retention Time repeatability<0.008% or <0.0008min
Peak Area Repeatability≤0.5% RSD

Injection Port

Injection PortSplit/Splitless
Maximum Operating Temperature450°C
Control Precision0.001 psi
Control Range0–100 psi
Gas Control ModesConstant pressure, constant flow, programmed pressure/flow ramps
Maximum Split Ratio12,500:1
Optional Carrier GasesN₂, H₂, He, Ar
Flow Rate Range (N₂ as carrier gas)0–500mL/min

Column Oven

Temperature RangeAmbient +4°C to 450°C
Programmable Temperature Ramps32 steps/33 platforms
Maximum Heating Rate≥75°C/min
Cooling Time (22°C ambient)From 450°C to 50°C in <5 minutes
Maximum Program Run Time9999.99 minutes

FID Detector

Maximum Operating Temperature450°C
Minimum Detectability≤1.5pg/s
Linear Range≥10⁷
DataAcquisition RateUp to 1000 Hz (provide proof of software interface)

ECD Detector

Minimum Detectability≤4×10⁻¹⁵ g/mL
Linear Rang≥10⁴

TCD Detector

Sensitivity≥60,000 mV·mL/mg
Linear Range≥10⁴
Instant Noise≤0.1 mV
Baseline Drift≤0.2 mV

Autosampler

Sample Capacity16 positions
Solvent Bottle Positions2
Waste Bottle Position1
Syringe Cleaning ModesStandalone, pre-injection, post-injection
Injection Volume0.1–5μL